[media] exynos4-is: Fix FIMC-IS clocks initialization
The ISP clock register content is not preserved over the ISP power domain off/on cycle. Instead of setting the clock frequencies once at probe time the clock rates set up is moved to the runtime_resume handler, which is invoked after the related power domain is already enabled, ensuring the clocks are properly configured when the device is actively used. This fixes the FIMC-IS malfunctions and STREAM ON timeout errors accuring on some boards: [ 59.860000] fimc_is_general_irq_handler:583 ISR_NDONE: 5: 0x800003e8, IS_ERROR_UNKNOWN [ 59.860000] fimc_is_general_irq_handler:586 IS_ERROR_TIME_OUT Signed-off-by: NSylwester Nawrocki <s.nawrocki@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com Signed-off-by: NMauro Carvalho Chehab <mchehab@redhat.com>
Showing
想要评论请 注册 或 登录