提交 6559b391 编写于 作者: S Simon Horman

ARM: dts: emev2: update PFC node name to pin-controller

The device trees for Renesas SoCs use either pfc or pin-controller as the
node name for the PFC device. This patch is intended to take a step towards
unifying the node name used as pin-controller which appears to be the more
generic of the two and thus more in keeping with the DT specs.

My analysis is that this is a user-visible change to the extent that kernel
logs, and sysfs entries change from e0140200.pfc and pfc@e0140200 to
e0140200.pin-controller and pin-controller@e0140200.
Signed-off-by: NSimon Horman <horms+renesas@verge.net.au>
Reviewed-by: NGeert Uytterhoeven <geert+renesas@glider.be>
上级 40c9bbea
...@@ -197,7 +197,7 @@ ...@@ -197,7 +197,7 @@
clock-names = "sclk"; clock-names = "sclk";
}; };
pfc: pfc@e0140200 { pfc: pin-controller@e0140200 {
compatible = "renesas,pfc-emev2"; compatible = "renesas,pfc-emev2";
reg = <0xe0140200 0x100>; reg = <0xe0140200 0x100>;
}; };
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册