提交 4fa11ec7 编写于 作者: S Sachin Kulkarni 提交者: Johannes Berg

mac80211: Requeue work after scan complete for all VIF types.

During a sw scan ieee80211_iface_work ignores work items for all vifs.
However after the scan complete work is requeued only for STA, ADHOC
and MESH iftypes.

This occasionally results in event processing getting delayed/not
processed for iftype AP when it coexists with a STA. This can result
in data halt and eventually disconnection on the AP interface.

Cc: stable@vger.kernel.org
Signed-off-by: NSachin Kulkarni <Sachin.Kulkarni@imgtec.com>
Signed-off-by: NJohannes Berg <johannes.berg@intel.com>
上级 da629cf1
......@@ -1733,7 +1733,6 @@ void ieee80211_ibss_notify_scan_completed(struct ieee80211_local *local)
if (sdata->vif.type != NL80211_IFTYPE_ADHOC)
continue;
sdata->u.ibss.last_scan_completed = jiffies;
ieee80211_queue_work(&local->hw, &sdata->work);
}
mutex_unlock(&local->iflist_mtx);
}
......
......@@ -1370,17 +1370,6 @@ void ieee80211_mesh_work(struct ieee80211_sub_if_data *sdata)
sdata_unlock(sdata);
}
void ieee80211_mesh_notify_scan_completed(struct ieee80211_local *local)
{
struct ieee80211_sub_if_data *sdata;
rcu_read_lock();
list_for_each_entry_rcu(sdata, &local->interfaces, list)
if (ieee80211_vif_is_mesh(&sdata->vif) &&
ieee80211_sdata_running(sdata))
ieee80211_queue_work(&local->hw, &sdata->work);
rcu_read_unlock();
}
void ieee80211_mesh_init_sdata(struct ieee80211_sub_if_data *sdata)
{
......
......@@ -362,14 +362,10 @@ static inline bool mesh_path_sel_is_hwmp(struct ieee80211_sub_if_data *sdata)
return sdata->u.mesh.mesh_pp_id == IEEE80211_PATH_PROTOCOL_HWMP;
}
void ieee80211_mesh_notify_scan_completed(struct ieee80211_local *local);
void mesh_path_flush_by_iface(struct ieee80211_sub_if_data *sdata);
void mesh_sync_adjust_tbtt(struct ieee80211_sub_if_data *sdata);
void ieee80211s_stop(void);
#else
static inline void
ieee80211_mesh_notify_scan_completed(struct ieee80211_local *local) {}
static inline bool mesh_path_sel_is_hwmp(struct ieee80211_sub_if_data *sdata)
{ return false; }
static inline void mesh_path_flush_by_iface(struct ieee80211_sub_if_data *sdata)
......
......@@ -4005,8 +4005,6 @@ static void ieee80211_restart_sta_timer(struct ieee80211_sub_if_data *sdata)
if (!ieee80211_hw_check(&sdata->local->hw, CONNECTION_MONITOR))
ieee80211_queue_work(&sdata->local->hw,
&sdata->u.mgd.monitor_work);
/* and do all the other regular work too */
ieee80211_queue_work(&sdata->local->hw, &sdata->work);
}
}
......
......@@ -314,6 +314,7 @@ static void __ieee80211_scan_completed(struct ieee80211_hw *hw, bool aborted)
bool was_scanning = local->scanning;
struct cfg80211_scan_request *scan_req;
struct ieee80211_sub_if_data *scan_sdata;
struct ieee80211_sub_if_data *sdata;
lockdep_assert_held(&local->mtx);
......@@ -373,7 +374,16 @@ static void __ieee80211_scan_completed(struct ieee80211_hw *hw, bool aborted)
ieee80211_mlme_notify_scan_completed(local);
ieee80211_ibss_notify_scan_completed(local);
ieee80211_mesh_notify_scan_completed(local);
/* Requeue all the work that might have been ignored while
* the scan was in progress; if there was none this will
* just be a no-op for the particular interface.
*/
list_for_each_entry_rcu(sdata, &local->interfaces, list) {
if (ieee80211_sdata_running(sdata))
ieee80211_queue_work(&sdata->local->hw, &sdata->work);
}
if (was_scanning)
ieee80211_start_next_roc(local);
}
......