提交 49c36dff 编写于 作者: J Jonathan Cameron 提交者: Greg Kroah-Hartman

staging:iio:documentation pull a few sysfs entries out of main docs.

These two attributes are only used in the one driver.  Whilst they
are fairly general I'm not entirely happy committing to them at
this stage.
Signed-off-by: NJonathan Cameron <jic23@kernel.org>
Signed-off-by: NGreg Kroah-Hartman <gregkh@linuxfoundation.org>
上级 8dc24597
......@@ -728,24 +728,3 @@ Contact: linux-iio@vger.kernel.org
Description:
This attribute is used to read the amount of quadrature error
present in the device at a given time.
What: /sys/.../iio:deviceX/ac_excitation_en
KernelVersion: 3.1.0
Contact: linux-iio@vger.kernel.org
Description:
This attribute, if available, is used to enable the AC
excitation mode found on some converters. In ac excitation mode,
the polarity of the excitation voltage is reversed on
alternate cycles, to eliminate DC errors.
What: /sys/.../iio:deviceX/bridge_switch_en
KernelVersion: 3.1.0
Contact: linux-iio@vger.kernel.org
Description:
This attribute, if available, is used to close or open the
bridge power down switch found on some converters.
In bridge applications, such as strain gauges and load cells,
the bridge itself consumes the majority of the current in the
system. To minimize the current consumption of the system,
the bridge can be disconnected (when it is not being used
using the bridge_switch_en attribute.
What: /sys/.../iio:deviceX/ac_excitation_en
KernelVersion: 3.1.0
Contact: linux-iio@vger.kernel.org
Description:
This attribute, if available, is used to enable the AC
excitation mode found on some converters. In ac excitation mode,
the polarity of the excitation voltage is reversed on
alternate cycles, to eliminate DC errors.
What: /sys/.../iio:deviceX/bridge_switch_en
KernelVersion: 3.1.0
Contact: linux-iio@vger.kernel.org
Description:
This attribute, if available, is used to close or open the
bridge power down switch found on some converters.
In bridge applications, such as strain gauges and load cells,
the bridge itself consumes the majority of the current in the
system. To minimize the current consumption of the system,
the bridge can be disconnected (when it is not being used
using the bridge_switch_en attribute.
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册