提交 40823f8e 编写于 作者: W Wei Ni 提交者: Zhang Rui

arm: tegra: set critical trips for Tegra124

Set general "critical" trip temperatures for cpu, gpu, mem and pllx
thermal zones for all Tegra124 platform, these trips can trigger
shut down or reset.
Tegra124 Jetson TK1 was already set "critical" trips before, so it
can overwrite the general values.
Signed-off-by: NWei Ni <wni@nvidia.com>
Signed-off-by: NZhang Rui <rui.zhang@intel.com>
上级 6c7c3245
......@@ -2045,44 +2045,32 @@
thermal-zones {
cpu {
trips {
trip {
cpu-shutdown-trip {
temperature = <101000>;
hysteresis = <0>;
type = "critical";
};
};
cooling-maps {
/* There are currently no cooling maps because there are no cooling devices */
};
};
mem {
trips {
trip {
mem-shutdown-trip {
temperature = <101000>;
hysteresis = <0>;
type = "critical";
};
};
cooling-maps {
/* There are currently no cooling maps because there are no cooling devices */
};
};
gpu {
trips {
trip {
gpu-shutdown-trip {
temperature = <101000>;
hysteresis = <0>;
type = "critical";
};
};
cooling-maps {
/* There are currently no cooling maps because there are no cooling devices */
};
};
};
};
......@@ -1154,6 +1154,21 @@
thermal-sensors =
<&soctherm TEGRA124_SOCTHERM_SENSOR_CPU>;
trips {
cpu-shutdown-trip {
temperature = <103000>;
hysteresis = <0>;
type = "critical";
};
};
cooling-maps {
/*
* There are currently no cooling maps,
* because there are no cooling devices.
*/
};
};
mem {
......@@ -1162,6 +1177,21 @@
thermal-sensors =
<&soctherm TEGRA124_SOCTHERM_SENSOR_MEM>;
trips {
mem-shutdown-trip {
temperature = <103000>;
hysteresis = <0>;
type = "critical";
};
};
cooling-maps {
/*
* There are currently no cooling maps,
* because there are no cooling devices.
*/
};
};
gpu {
......@@ -1170,6 +1200,21 @@
thermal-sensors =
<&soctherm TEGRA124_SOCTHERM_SENSOR_GPU>;
trips {
gpu-shutdown-trip {
temperature = <101000>;
hysteresis = <0>;
type = "critical";
};
};
cooling-maps {
/*
* There are currently no cooling maps,
* because there are no cooling devices.
*/
};
};
pllx {
......@@ -1178,6 +1223,21 @@
thermal-sensors =
<&soctherm TEGRA124_SOCTHERM_SENSOR_PLLX>;
trips {
pllx-shutdown-trip {
temperature = <103000>;
hysteresis = <0>;
type = "critical";
};
};
cooling-maps {
/*
* There are currently no cooling maps,
* because there are no cooling devices.
*/
};
};
};
......