nohz: fix wrong event handler after online an offlined cpu
On the tickless system(CONFIG_NO_HZ=y and CONFIG_HIGH_RES_TIMERS=n), after I made an offlined cpu online, I found this cpu's event handler was tick_handle_periodic, not tick_nohz_handler. After debuging, I found this bug was caused by the wrong tick mode. the tick mode is not changed to NOHZ_MODE_INACTIVE when the cpu is offline. This patch fixes this bug. Signed-off-by: NMiao Xie <miaox@cn.fujitsu.com> Signed-off-by: NAndrew Morton <akpm@linux-foundation.org> Signed-off-by: NIngo Molnar <mingo@elte.hu>