ath9k_hw: Fix Tx IQ Calibration hang issue in AR9003 chips
On AR9003 chips, doing three IQ calibrations will possibly cause chip in stuck state. In noisy environment, chip could receive a packet during the middle of three calibrations and it causes the conflict of HW access and the eventual failure. It also causes IQ calibration outliers which results in poor Tx EVM. The IQ Cal procedure is after resetting the chip, run IQ cal 3 times per each cal cycle and find the two closest readings and average of two. The advantage of running Tx IQ cal more than once is that we can compare calibration results for the same gain setting over multiple iterations. Most of the cases the IQ failures were observed after first pass. For the AR9485 and later chips, Tx IQ Calibration is performed along with AGC cal. But for pre-AR9485 chips, Tx IQ cal HW has to be separated from the rest of calibration HW to avoid chip hang. After all calibrations are done in HW, we can start SW post-processing. By doing this way, we minimize the SW difference among all chips. The order of calibration (run IQ cal before other calibration) is also needed to avoid chip hang for chips before AR9485. This issue was originally observed with AR9382. During the issue kernel log was filled with following message ath: timeout (100000 us) on reg 0xa640: 0x00000001 & 0x00000001 != 0x00000000 ath: timeout (100000 us) on reg 0xa2c4: 0x00158dd9 & 0x00000001 != 0x00000000 ath: Unable to reset channel (2412 MHz), reset status -5 ath: Unable to set channel Signed-off-by: NRajkumar Manoharan <rmanoharan@atheros.com> Signed-off-by: NJohn W. Linville <linville@tuxdriver.com>