drm/nouveau/therm: force a minimum hysteresis on temperature alarm thresholds

This should avoid the situation where a user gets its kernel logs flooded when
temperature oscillates around a threshold with 0°C hysteresis.

This patch is just meant to fix broken vbios (as reported on a nv4e on
sysfs hwmon interface.
Signed-off-by: NMartin Peres <martin.peres@labri.fr>
Signed-off-by: NBen Skeggs <bskeggs@redhat.com>
上级 f1aa4a1d
......@@ -58,11 +58,18 @@ static void
nouveau_therm_temp_safety_checks(struct nouveau_therm *therm)
{
struct nouveau_therm_priv *priv = (void *)therm;
struct nvbios_therm_sensor *s = &priv->bios_sensor;
if (!priv->bios_sensor.slope_div)
priv->bios_sensor.slope_div = 1;
if (!priv->bios_sensor.offset_den)
priv->bios_sensor.offset_den = 1;
/* enforce a minimum hysteresis on thresholds */
s->thrs_fan_boost.hysteresis = max_t(u8, s->thrs_fan_boost.hysteresis, 2);
s->thrs_down_clock.hysteresis = max_t(u8, s->thrs_down_clock.hysteresis, 2);
s->thrs_critical.hysteresis = max_t(u8, s->thrs_critical.hysteresis, 2);
s->thrs_shutdown.hysteresis = max_t(u8, s->thrs_shutdown.hysteresis, 2);
}
/* must be called with alarm_program_lock taken ! */
......