staging: comedi: addi_apci_1032: conform to new INSN_CONFIG_DIGITAL_TRIG
Conform to the new definition of the `INSN_CONFIG_DIGITAL_TRIG` configuration instruction. Return an error if the 'trigger number' in `data[1]` is non-zero or if the configuration operation in `data[2]` is not supported. Deal with the 'left-shift' amount in `data[3]`. The trigger's input channels can only be configured as a set of rising and falling edges ('OR' mode) or as a set of high and low levels ('AND' mode). Preserve the old input channels to the right of the 'left-shift' value except when switching modes. (The 'left-shift' support is a bit of an overkill for this driver since the trigger only has 16 input channels.) Signed-off-by: NIan Abbott <abbotti@mev.co.uk> Signed-off-by: NGreg Kroah-Hartman <gregkh@linuxfoundation.org>