提交 2e3f7f26 编写于 作者: A Axel Lin 提交者: Mark Brown

regulator: max77686: Use regulator_map_voltage_linear for simple linear mappings

Both max77686_ops and max77686_buck_dvs_ops use simple linear voltage maps.
Thus use regulator_map_voltage_linear is more efficient than using the defult
regulator_map_voltage_iterate.
Signed-off-by: NAxel Lin <axel.lin@gmail.com>
Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
上级 fcbb71f6
...@@ -90,6 +90,7 @@ static int max77686_set_voltage_time_sel(struct regulator_dev *rdev, ...@@ -90,6 +90,7 @@ static int max77686_set_voltage_time_sel(struct regulator_dev *rdev,
static struct regulator_ops max77686_ops = { static struct regulator_ops max77686_ops = {
.list_voltage = regulator_list_voltage_linear, .list_voltage = regulator_list_voltage_linear,
.map_voltage = regulator_map_voltage_linear,
.is_enabled = regulator_is_enabled_regmap, .is_enabled = regulator_is_enabled_regmap,
.enable = regulator_enable_regmap, .enable = regulator_enable_regmap,
.disable = regulator_disable_regmap, .disable = regulator_disable_regmap,
...@@ -100,6 +101,7 @@ static struct regulator_ops max77686_ops = { ...@@ -100,6 +101,7 @@ static struct regulator_ops max77686_ops = {
static struct regulator_ops max77686_buck_dvs_ops = { static struct regulator_ops max77686_buck_dvs_ops = {
.list_voltage = regulator_list_voltage_linear, .list_voltage = regulator_list_voltage_linear,
.map_voltage = regulator_map_voltage_linear,
.is_enabled = regulator_is_enabled_regmap, .is_enabled = regulator_is_enabled_regmap,
.enable = regulator_enable_regmap, .enable = regulator_enable_regmap,
.disable = regulator_disable_regmap, .disable = regulator_disable_regmap,
......