提交 22d2e402 编写于 作者: B Brian King 提交者: James Bottomley

[SCSI] ipr: Increase adapter operational timeout

Increases the adapter operational timeout for some adapters that support
dual controller configurations, since they may take longer to come ready.
Signed-off-by: NBrian King <brking@linux.vnet.ibm.com>
Signed-off-by: NJames Bottomley <James.Bottomley@SteelEye.com>
上级 65f56475
......@@ -7611,19 +7611,22 @@ static struct pci_device_id ipr_pci_table[] __devinitdata = {
{ PCI_VENDOR_ID_ADAPTEC2, PCI_DEVICE_ID_ADAPTEC2_OBSIDIAN,
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_572A, 0, 0, 0 },
{ PCI_VENDOR_ID_ADAPTEC2, PCI_DEVICE_ID_ADAPTEC2_OBSIDIAN,
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_572B, 0, 0, 0 },
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_572B, 0, 0,
IPR_USE_LONG_TRANSOP_TIMEOUT },
{ PCI_VENDOR_ID_ADAPTEC2, PCI_DEVICE_ID_ADAPTEC2_OBSIDIAN,
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_575C, 0, 0,
IPR_USE_LONG_TRANSOP_TIMEOUT },
{ PCI_VENDOR_ID_IBM, PCI_DEVICE_ID_IBM_OBSIDIAN,
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_572A, 0, 0, 0 },
{ PCI_VENDOR_ID_IBM, PCI_DEVICE_ID_IBM_OBSIDIAN,
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_572B, 0, 0, 0 },
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_572B, 0, 0,
IPR_USE_LONG_TRANSOP_TIMEOUT},
{ PCI_VENDOR_ID_IBM, PCI_DEVICE_ID_IBM_OBSIDIAN,
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_575C, 0, 0,
IPR_USE_LONG_TRANSOP_TIMEOUT },
{ PCI_VENDOR_ID_IBM, PCI_DEVICE_ID_IBM_OBSIDIAN_E,
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_574E, 0, 0, 0 },
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_574E, 0, 0,
IPR_USE_LONG_TRANSOP_TIMEOUT },
{ PCI_VENDOR_ID_IBM, PCI_DEVICE_ID_IBM_OBSIDIAN_E,
PCI_VENDOR_ID_IBM, IPR_SUBS_DEV_ID_575D, 0, 0,
IPR_USE_LONG_TRANSOP_TIMEOUT },
......
Markdown is supported