提交 0b03fd85 编写于 作者: Q Qianqian Xie 提交者: David S. Miller

net: hns: bug fix of ge reset sequence

The bit fileds of PPE reset register are different between HNS v1 and
HNS v2, but the current procedure just only match HNS v1. Here is a
patch to fix it.
Signed-off-by: NKejian Yan <yankejian@huawei.com>
Signed-off-by: NQianqian Xie <xieqianqian@huawei.com>
Signed-off-by: NYisen Zhuang <Yisen.Zhuang@huawei.com>
Signed-off-by: NDavid S. Miller <davem@davemloft.net>
上级 4906ce45
......@@ -271,7 +271,11 @@ static void hns_dsaf_ge_srst_by_port(struct dsaf_device *dsaf_dev, u32 port,
}
} else {
reg_val_1 = 0x15540 << dsaf_dev->reset_offset;
reg_val_2 = 0x100 << dsaf_dev->reset_offset;
if (AE_IS_VER1(dsaf_dev->dsaf_ver))
reg_val_2 = 0x100 << dsaf_dev->reset_offset;
else
reg_val_2 = 0x40 << dsaf_dev->reset_offset;
if (!dereset) {
dsaf_write_sub(dsaf_dev, DSAF_SUB_SC_GE_RESET_REQ1_REG,
......