提交 0873a5ae 编写于 作者: E Erik J. Staab 提交者: Takashi Iwai

ALSA: oxygen: fix analog capture on Claro halo cards

On the HT-Omega Claro halo card, the ADC data must be captured from the
second I2S input.  Using the default first input, which isn't connected
to anything, would result in silence.
Signed-off-by: NErik J. Staab <ejs@insightbb.com>
Signed-off-by: NClemens Ladisch <clemens@ladisch.de>
Cc: <stable@kernel.org>
Signed-off-by: NTakashi Iwai <tiwai@suse.de>
上级 b30a3f62
......@@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip,
chip->model.suspend = claro_suspend;
chip->model.resume = claro_resume;
chip->model.set_adc_params = set_ak5385_params;
chip->model.device_config = PLAYBACK_0_TO_I2S |
PLAYBACK_1_TO_SPDIF |
CAPTURE_0_FROM_I2S_2 |
CAPTURE_1_FROM_SPDIF;
break;
}
if (id->driver_data == MODEL_MERIDIAN ||
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册