提交 06cc5d3b 编写于 作者: V Vidhya Govindan 提交者: John W. Linville

wl1251: Send null data packet with "TODS" bit set

According to IEEE80211 standard all the data packets have to be sent with
TODS bit set. This patch fixes the null data packet format which was sent
without TODS bit set. This should fix many problems associated with
power save. Janne Ylalehto also found this fix in the same time as mine,
for a different bug he was working on.
Signed-off-by: NVidhya Govindan <vidhya.govindan@nokia.com>
Reviewed-by: NJanne Ylalehto <janne.ylalehto@nokia.com>
Signed-off-by: NKalle Valo <kalle.valo@nokia.com>
Signed-off-by: NJohn W. Linville <linville@tuxdriver.com>