提交 03a58baa 编写于 作者: K Kalesh AP 提交者: David S. Miller

be2net: enable interrupts in EEH resume

On some BE3 FW versions, after a HW reset, interrupts will remain disabled
for each function. So, explicitly enable the interrupts in the eeh_resume
handler, else after an eeh recovery interrupts wouldn't work.
Signed-off-by: NKalesh AP <kalesh.purayil@emulex.com>
Signed-off-by: NSathya Perla <sathya.perla@emulex.com>
Signed-off-by: NDavid S. Miller <davem@davemloft.net>
上级 c4b16068
......@@ -4949,6 +4949,12 @@ static void be_eeh_resume(struct pci_dev *pdev)
if (status)
goto err;
/* On some BE3 FW versions, after a HW reset,
* interrupts will remain disabled for each function.
* So, explicitly enable interrupts
*/
be_intr_set(adapter, true);
/* tell fw we're ready to fire cmds */
status = be_cmd_fw_init(adapter);
if (status)
......