• M
    powernow-k6: correctly initialize default parameters · d82b922a
    Mikulas Patocka 提交于
    The powernow-k6 driver used to read the initial multiplier from the
    powernow register. However, there is a problem with this:
    
    * If there was a frequency transition before, the multiplier read from the
      register corresponds to the current multiplier.
    * If there was no frequency transition since reset, the field in the
      register always reads as zero, regardless of the current multiplier that
      is set using switches on the mainboard and that the CPU is running at.
    
    The zero value corresponds to multiplier 4.5, so as a consequence, the
    powernow-k6 driver always assumes multiplier 4.5.
    
    For example, if we have 550MHz CPU with bus frequency 100MHz and
    multiplier 5.5, the powernow-k6 driver thinks that the multiplier is 4.5
    and bus frequency is 122MHz. The powernow-k6 driver then sets the
    multiplier to 4.5, underclocking the CPU to 450MHz, but reports the
    current frequency as 550MHz.
    
    There is no reliable way how to read the initial multiplier. I modified
    the driver so that it contains a table of known frequencies (based on
    parameters of existing CPUs and some common overclocking schemes) and sets
    the multiplier according to the frequency. If the frequency is unknown
    (because of unusual overclocking or underclocking), the user must supply
    the bus speed and maximum multiplier as module parameters.
    
    This patch should be backported to all stable kernels. If it doesn't
    apply cleanly, change it, or ask me to change it.
    Signed-off-by: NMikulas Patocka <mpatocka@redhat.com>
    Signed-off-by: NRafael J. Wysocki <rafael.j.wysocki@intel.com>