由 Lars-Peter Clausen 提交于
[ Upstream commit df1d80aee963480c5c2938c64ec0ac3e4a0df2e0 ] For devices from the SigmaDelta family we need to keep CS low when doing a conversion, since the device will use the MISO line as a interrupt to indicate that the conversion is complete. This is why the driver locks the SPI bus and when the SPI bus is locked keeps as long as a conversion is going on. The current implementation gets one small detail wrong though. CS is only de-asserted after the SPI bus is unlocked. This means it is possible for a different SPI device on the same bus to send a message which would be wrongfully be addressed to the SigmaDelta device as well. Make sure that the last SPI transfer that is done while holding the SPI bus lock de-asserts the CS signal. Signed-off-by: NLars-Peter Clausen <lars@metafoo.de> Signed-off-by: NAlexandru Ardelean <Alexandru.Ardelean@analog.com> Signed-off-by: NJonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: NSasha Levin <sashal@kernel.org>
d7c77341