• I
    ARM: pxa: ulpi: fix ulpi timeout and slowpath warn · 7a5d9a91
    Igor Grinberg 提交于
    Both cm-x300 and pxa3xx-ulpi use the plain clk_{en,dis}able() API.
    With the new clocking framework this results in warnings of type:
    ------------[ cut here ]------------
    WARNING: CPU: 0 PID: 1 at drivers/clk/clk.c:714 clk_core_enable+0x90/0x9c
    Modules linked in:
    CPU: 0 PID: 1 Comm: swapper Not tainted 4.15.0-rc5-cm-x300+ #15
    Hardware name: CM-X300 module
    [<c001007c>] (unwind_backtrace) from [<c000df94>] (show_stack+0x10/0x14)
    [<c000df94>] (show_stack) from [<c00199a8>] (__warn+0xd8/0x100)
    [<c00199a8>] (__warn) from [<c0019a0c>] (warn_slowpath_null+0x3c/0x48)
    [<c0019a0c>] (warn_slowpath_null) from [<c024e8c0>] (clk_core_enable+0x90/0x9c)
    [<c024e8c0>] (clk_core_enable) from [<c024ea54>] (clk_core_enable_lock+0x18/0x2c)
    [<c024ea54>] (clk_core_enable_lock) from [<c0016994>] (cm_x300_u2d_init+0x4c/0xe8)
    [<c0016994>] (cm_x300_u2d_init) from [<c00163e0>] (pxa3xx_u2d_probe+0xe0/0x244)
    [<c00163e0>] (pxa3xx_u2d_probe) from [<c0283de0>] (platform_drv_probe+0x38/0x88)
    ...
    ------------[ cut here ]------------
    and alike...
    
    And finally, it results in:
    ------------[ cut here ]------------
    pxa310_ulpi_poll: ULPI access timed out!
    OTG transceiver init failed
    ------------[ cut here ]------------
    
    It might be that disabling the warning in kernel config would also do
    the job, but IMO a better solution would be to switch to
    clk_prepare_enable() and clk_disable_unprepare() APIs.
    Signed-off-by: NIgor Grinberg <grinberg@compulab.co.il>
    Signed-off-by: NRobert Jarzmik <robert.jarzmik@free.fr>
    7a5d9a91