• O
    can: m_can: tag current CAN FD controllers as non-ISO · 6cfda7fb
    Oliver Hartkopp 提交于
    During the CAN FD standardization process within the ISO it turned out that
    the failure detection capability has to be improved.
    
    The CAN in Automation organization (CiA) defined the already implemented CAN
    FD controllers as 'non-ISO' and the upcoming improved CAN FD controllers as
    'ISO' compliant. See at http://www.can-cia.com/index.php?id=1937
    
    Finally there will be three types of CAN FD controllers in the future:
    
    1. ISO compliant (fixed)
    2. non-ISO compliant (fixed, like the M_CAN IP v3.0.1 in m_can.c)
    3. ISO/non-ISO CAN FD controllers (switchable, like the PEAK USB FD)
    
    So the current M_CAN driver for the M_CAN IP v3.0.1 has to expose its non-ISO
    implementation by setting the CAN_CTRLMODE_FD_NON_ISO ctrlmode at startup.
    As this bit cannot be switched at configuration time CAN_CTRLMODE_FD_NON_ISO
    must not be set in ctrlmode_supported of the current M_CAN driver.
    Signed-off-by: NOliver Hartkopp <socketcan@hartkopp.net>
    Cc: linux-stable <stable@vger.kernel.org>
    Signed-off-by: NMarc Kleine-Budde <mkl@pengutronix.de>
    6cfda7fb
m_can.c 31.5 KB