由 Michal Kazior 提交于
When QCA988X cycle counter HW register wraps around it resets to 0x7fffffff instead of 0. All other cycle counter related registers are divided by 2 so they never wraparound themselves. QCA61X4 has a uniform CC and it wraparounds in a regular fashion though. Worst case wraparound time is approx 24 seconds (2**31 / 88MHz). Since scan channel visit times are max 5 seconds (offchannel case) it is guaranteed there's been at most 1 wraparound and it is possible to compute survey active time value. It is, however, impossible to determine the point at which Rx Clear Count has been divided by two so it is not reported upon wraparound. This fixes some occasional incorrect survey data on QCA988X as some channels (depending on how/when scan/offchannel requests were requested) would have approx 24 sec active time which wasn't actually the case. This should improve hostapd ACS a little bit. Reported-by: NSrinivasa Duvvuri <sduvvuri@chromium.org> Signed-off-by: NMichal Kazior <michal.kazior@tieto.com> Signed-off-by: NKalle Valo <kvalo@qca.qualcomm.com>