由 Robin van der Gracht 提交于
When the ADC is being prepared for a single or multiple channel reading, the adc0 register is reconfigured without taking the lithium cell, charge current and battery current reading enable bits into account. Which results in clearing the bits. Signed-off-by: NRobin van der Gracht <robin@protonic.nl> Signed-off-by: NSamuel Ortiz <sameo@linux.intel.com>