由 Adrian Knoth 提交于
The RayDAT reports the sync status of its inputs in consecutive bit positions, so all we do in hdspm_s1_sync_check is to iterate over idx: status = hdspm_read(hdspm, HDSPM_RD_STATUS_1); lock = (status & (0x1<<idx)) ? 1 : 0; sync = (status & (0x100<<idx)) ? 1 : 0; The index is given in kcontrol->private_value: HDSPM_SYNC_CHECK("WC SyncCheck", 0), HDSPM_SYNC_CHECK("AES SyncCheck", 1), HDSPM_SYNC_CHECK("SPDIF SyncCheck", 2), HDSPM_SYNC_CHECK("ADAT1 SyncCheck", 3), HDSPM_SYNC_CHECK("ADAT2 SyncCheck", 4), HDSPM_SYNC_CHECK("ADAT3 SyncCheck", 5), HDSPM_SYNC_CHECK("ADAT4 SyncCheck", 6), HDSPM_SYNC_CHECK("TCO SyncCheck", 7), HDSPM_SYNC_CHECK("SYNC IN SyncCheck", 8), The patch corrects the indicated sync flags by passing the proper index value to hdspm_s1_sync_check(). Signed-off-by: NAdrian Knoth <adi@drcomp.erfurt.thur.de> Signed-off-by: NTakashi Iwai <tiwai@suse.de>
d1a3c98d