由 Kamenee Arumugam 提交于
HFI's counters SendWaitCnt and SendWaitVlCnt are in units of TXE cycle time (at 805MHz). OPA counters PortXmitWait and PortVLXmtWait are in units of flit times. Convert the counter values to flit units using following conversion formula: PortXmitWait = SendWaitCnt * 2 * (4 /link_width) * (25 Gbps /link_speed) PortVLXmitWait = SendWaitVLCnt * 2 * (4 /link_width) * (25 Gbps /link_speed) At link up or downgrade events, the link width can change. To ensure accurate counter calculations, sample the counters after the events, during counter requests, and then aggregate the OPA counters. Reviewed-by: NMichael J. Ruhl <michael.j.ruhl@intel.com> Signed-off-by: NKamenee Arumugam <kamenee.arumugam@intel.com> Signed-off-by: NDennis Dalessandro <dennis.dalessandro@intel.com> Signed-off-by: NJason Gunthorpe <jgg@mellanox.com>
07190076