vgic-init.c 3.0 KB
Newer Older
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123
/*
 * Copyright (C) 2015, 2016 ARM Ltd.
 *
 * This program is free software; you can redistribute it and/or modify
 * it under the terms of the GNU General Public License version 2 as
 * published by the Free Software Foundation.
 *
 * This program is distributed in the hope that it will be useful,
 * but WITHOUT ANY WARRANTY; without even the implied warranty of
 * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
 * GNU General Public License for more details.
 *
 * You should have received a copy of the GNU General Public License
 * along with this program.  If not, see <http://www.gnu.org/licenses/>.
 */

#include <linux/uaccess.h>
#include <linux/interrupt.h>
#include <linux/cpu.h>
#include <linux/kvm_host.h>
#include <kvm/arm_vgic.h>
#include <asm/kvm_mmu.h>
#include "vgic.h"

/* GENERIC PROBE */

static void vgic_init_maintenance_interrupt(void *info)
{
	enable_percpu_irq(kvm_vgic_global_state.maint_irq, 0);
}

static int vgic_cpu_notify(struct notifier_block *self,
			   unsigned long action, void *cpu)
{
	switch (action) {
	case CPU_STARTING:
	case CPU_STARTING_FROZEN:
		vgic_init_maintenance_interrupt(NULL);
		break;
	case CPU_DYING:
	case CPU_DYING_FROZEN:
		disable_percpu_irq(kvm_vgic_global_state.maint_irq);
		break;
	}

	return NOTIFY_OK;
}

static struct notifier_block vgic_cpu_nb = {
	.notifier_call = vgic_cpu_notify,
};

static irqreturn_t vgic_maintenance_handler(int irq, void *data)
{
	/*
	 * We cannot rely on the vgic maintenance interrupt to be
	 * delivered synchronously. This means we can only use it to
	 * exit the VM, and we perform the handling of EOIed
	 * interrupts on the exit path (see vgic_process_maintenance).
	 */
	return IRQ_HANDLED;
}

/**
 * kvm_vgic_hyp_init: populates the kvm_vgic_global_state variable
 * according to the host GIC model. Accordingly calls either
 * vgic_v2/v3_probe which registers the KVM_DEVICE that can be
 * instantiated by a guest later on .
 */
int kvm_vgic_hyp_init(void)
{
	const struct gic_kvm_info *gic_kvm_info;
	int ret;

	gic_kvm_info = gic_get_kvm_info();
	if (!gic_kvm_info)
		return -ENODEV;

	if (!gic_kvm_info->maint_irq) {
		kvm_err("No vgic maintenance irq\n");
		return -ENXIO;
	}

	switch (gic_kvm_info->type) {
	case GIC_V2:
		ret = vgic_v2_probe(gic_kvm_info);
		break;
	case GIC_V3:
		ret = vgic_v3_probe(gic_kvm_info);
		break;
	default:
		ret = -ENODEV;
	};

	if (ret)
		return ret;

	kvm_vgic_global_state.maint_irq = gic_kvm_info->maint_irq;
	ret = request_percpu_irq(kvm_vgic_global_state.maint_irq,
				 vgic_maintenance_handler,
				 "vgic", kvm_get_running_vcpus());
	if (ret) {
		kvm_err("Cannot register interrupt %d\n",
			kvm_vgic_global_state.maint_irq);
		return ret;
	}

	ret = __register_cpu_notifier(&vgic_cpu_nb);
	if (ret) {
		kvm_err("Cannot register vgic CPU notifier\n");
		goto out_free_irq;
	}

	on_each_cpu(vgic_init_maintenance_interrupt, NULL, 1);

	kvm_info("vgic interrupt IRQ%d\n", kvm_vgic_global_state.maint_irq);
	return 0;

out_free_irq:
	free_percpu_irq(kvm_vgic_global_state.maint_irq,
			kvm_get_running_vcpus());
	return ret;
}