marvell-armada-370-neta.txt 864 字节
Newer Older
1 2 3
* Marvell Armada 370 / Armada XP Ethernet Controller (NETA)

Required properties:
4
- compatible: "marvell,armada-370-neta" or "marvell,armada-xp-neta".
5 6
- reg: address and length of the register set for the device.
- interrupts: interrupt for the device
7 8
- phy: See ethernet.txt file in the same directory.
- phy-mode: See ethernet.txt file in the same directory
T
Thomas Petazzoni 已提交
9
- clocks: a pointer to the reference clock for this device.
10

11 12 13 14 15
Optional properties:
- tx-csum-limit: maximum mtu supported by port that allow TX checksum.
  Value is presented in bytes. If not used, by default 1600B is set for
  "marvell,armada-370-neta" and 9800B for others.

16 17 18 19 20 21
Example:

ethernet@d0070000 {
	compatible = "marvell,armada-370-neta";
	reg = <0xd0070000 0x2500>;
	interrupts = <8>;
T
Thomas Petazzoni 已提交
22
	clocks = <&gate_clk 4>;
23
	tx-csum-limit = <9800>
24 25 26 27
	status = "okay";
	phy = <&phy0>;
	phy-mode = "rgmii-id";
};