      aspeed/timer: use the APB frequency from the SCU · 9b945a9e
      Cédric Le Goater 提交于
      The timer controller can be driven by either an external 1MHz clock or
      by the APB clock. Today, the model makes the assumption that the APB
      frequency is always set to 24MHz but this is incorrect.
      
      The AST2400 SoC on the palmetto machines uses a 48MHz input clock
      source and the APB can be set to 48MHz. The consequence is a general
      system slowdown. The QEMU machines using the AST2500 SoC do not seem
      impacted today because the APB frequency is still set to 24MHz.
      
      We fix the timer frequency for all SoCs by linking the Timer model to
      the SCU model. The APB frequency driving the timers is now the one
      configured for the SoC.
      Signed-off-by: NCédric Le Goater <clg@kaod.org>
      Reviewed-by: NJoel Stanley <joel@jms.id.au>
      Reviewed-by: NAndrew Jeffery <andrew@aj.id.au>
      Message-id: 20180622075700.5923-4-clg@kaod.org
      Signed-off-by: NPeter Maydell <peter.maydell@linaro.org>
      9b945a9e