提交 a1c1baf0 编写于 作者: N Nikolaus Schulz 提交者: Guenter Roeck

hwmon: (f75375s) Let f75375_update_device treat pwmX as a measured value

Treat pwmX as a measured value, not as a (mostly static) limit value, so
that it is updated more frequently from the device register.
Signed-off-by: NNikolaus Schulz <mail@microschulz.de>
Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com>
上级 eb2f255b
......@@ -200,9 +200,6 @@ static struct f75375_data *f75375_update_device(struct device *dev)
f75375_read16(client, F75375_REG_FAN_MIN(nr));
data->fan_target[nr] =
f75375_read16(client, F75375_REG_FAN_EXP(nr));
data->pwm[nr] = f75375_read8(client,
F75375_REG_FAN_PWM_DUTY(nr));
}
for (nr = 0; nr < 4; nr++) {
data->in_max[nr] =
......@@ -218,6 +215,8 @@ static struct f75375_data *f75375_update_device(struct device *dev)
if (time_after(jiffies, data->last_updated + 2 * HZ)
|| !data->valid) {
for (nr = 0; nr < 2; nr++) {
data->pwm[nr] = f75375_read8(client,
F75375_REG_FAN_PWM_DUTY(nr));
/* assign MSB, therefore shift it by 8 bits */
data->temp11[nr] =
f75375_read8(client, F75375_REG_TEMP(nr)) << 8;
......