提交 fcbedd0f 编写于 作者: I Intiyaz Basha 提交者: David S. Miller

liquidio: Resolved mbox read issue while reading more than one 64bit data

Corrected length check when data received in the mbox is more than one
64 bit data value
Signed-off-by: NIntiyaz Basha <intiyaz.basha@cavium.com>
Signed-off-by: NFelix Manlunas <felix.manlunas@cavium.com>
Signed-off-by: NDavid S. Miller <davem@davemloft.net>
上级 fd372a7a
......@@ -87,7 +87,7 @@ int octeon_mbox_read(struct octeon_mbox *mbox)
}
if (mbox->state & OCTEON_MBOX_STATE_REQUEST_RECEIVING) {
if (mbox->mbox_req.recv_len < msg.s.len) {
if (mbox->mbox_req.recv_len < mbox->mbox_req.msg.s.len) {
ret = 0;
} else {
mbox->state &= ~OCTEON_MBOX_STATE_REQUEST_RECEIVING;
......@@ -96,7 +96,8 @@ int octeon_mbox_read(struct octeon_mbox *mbox)
}
} else {
if (mbox->state & OCTEON_MBOX_STATE_RESPONSE_RECEIVING) {
if (mbox->mbox_resp.recv_len < msg.s.len) {
if (mbox->mbox_resp.recv_len <
mbox->mbox_resp.msg.s.len) {
ret = 0;
} else {
mbox->state &=
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册