提交 ee3ed6ef 编写于 作者: A Axel Lin 提交者: Mark Brown

regulator: da903x: Don't read/write to DA9030_INVAL/DA9034_INVAL address

For fixed voltage, DA9030_LDO13 and DA9034_LDO5, the info->vol_reg is
DA9030_INVAL/DA9034_INVAL.
It does not make sense to read/write to DA9030_INVAL/DA9034_INVAL address.
Signed-off-by: NAxel Lin <axel.lin@gmail.com>
Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
上级 985f769c
......@@ -107,6 +107,9 @@ static int da903x_set_voltage_sel(struct regulator_dev *rdev, unsigned selector)
struct device *da9034_dev = to_da903x_dev(rdev);
uint8_t val, mask;
if (rdev->desc->n_voltages == 1)
return -EINVAL;
val = selector << info->vol_shift;
mask = ((1 << info->vol_nbits) - 1) << info->vol_shift;
......@@ -120,6 +123,9 @@ static int da903x_get_voltage_sel(struct regulator_dev *rdev)
uint8_t val, mask;
int ret;
if (rdev->desc->n_voltages == 1)
return 0;
ret = da903x_read(da9034_dev, info->vol_reg, &val);
if (ret)
return ret;
......