提交 1621dbbd 编写于 作者: A Andrew Vasquez 提交者: James Bottomley

[SCSI] qla2xxx: Return DID_NO_CONNECT when FC device is lost.

If the target device gets lost, this fix is needed, as it causes
negative unintended responses on basic I/O tests. If the target device
gets lost, the upstream qla2xxx driver returns
SCSI_MLQUEUE_TARGET_BUSY which causes an immediate retry without drop
in the number of allowed retries. This semantic change, as a result of
removing FC_DEVICE_LOST check is reasonable, as it only extends a
short transitional period, until the transport is called to notify
that the rport as lost (fc_remote_port_delete()). Once transport
notification is done, fc_remote_port_chkready() check will take over.
Signed-off-by: NAndrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: NMadhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: NJames Bottomley <James.Bottomley@suse.de>
上级 d2b21476
......@@ -562,7 +562,6 @@ qla2xxx_queuecommand_lck(struct scsi_cmnd *cmd, void (*done)(struct scsi_cmnd *)
}
if (atomic_read(&fcport->state) != FCS_ONLINE) {
if (atomic_read(&fcport->state) == FCS_DEVICE_DEAD ||
atomic_read(&fcport->state) == FCS_DEVICE_LOST ||
atomic_read(&base_vha->loop_state) == LOOP_DEAD) {
cmd->result = DID_NO_CONNECT << 16;
goto qc24_fail_command;
......