In remove, the clock is disabled before canceling the delayed work. This means that the delayed work may be touching unclocked hardware. Fix by disabling the clock after the delayed work is fully canceled. This is consistent with the probe error path order. Signed-off-by: NSven Van Asbroeck <TheSven73@gmail.com> Signed-off-by: NJonathan Cameron <Jonathan.Cameron@huawei.com>