- 08 2月, 2011 7 次提交
-
-
由 René Moser 提交于
-
由 René Moser 提交于
-
由 René Moser 提交于
-
由 Kohsuke Kawaguchi 提交于
-
由 Kohsuke Kawaguchi 提交于
-
由 Kohsuke Kawaguchi 提交于
-
由 Kohsuke Kawaguchi 提交于
-
- 07 2月, 2011 3 次提交
-
-
由 Jerome Lacoste 提交于
Note that the above description is incorrect as to what the merge was about. It is the message that I intended to make. It appears that I accidentaly merged multiple fixes waiting to be reviewed on my private fork. This reverts commit dce0d2af, reversing changes made to 63f67f30.
-
由 Jerome Lacoste 提交于
-
由 Jerome Lacoste 提交于
-
- 05 2月, 2011 30 次提交
-
-
由 Jerome Lacoste 提交于
hudson.UDPBroadcastThread#testMulticast hangs when the network isn't enabled on my Linux box: joinGroup throws IOException and the ready lock isn't released. This ready lock is only used in the tests.
-
由 Jerome Lacoste 提交于
-
由 Jerome Lacoste 提交于
It is slow and take 10sec on my compiter. Disabling it. One could remove it I guess.
-
由 Jerome Lacoste 提交于
JENKINS-8702 improve unit tests. UpdateCenterTest depends on online resource and takes too long. Fix this
-
由 Kohsuke Kawaguchi 提交于
Looks like I broke this in d88df7ea
-
由 Kohsuke Kawaguchi 提交于
-
由 Jerome Lacoste 提交于
Reapplied 329a0201 Conflicts: core/src/main/java/hudson/widgets/HistoryWidget.java
-
由 Kohsuke Kawaguchi 提交于
-
由 Kohsuke Kawaguchi 提交于
* JENKINS-4756: minor touch up FIXED JENKINS-4756 the executor number was not always unique. Computer.executors.size() does not provide a unique number within one Computer.
-
由 Kohsuke Kawaguchi 提交于
-
由 Kohsuke Kawaguchi 提交于
-
由 Kohsuke Kawaguchi 提交于
* JENKINS-8660: fail more gracefully if the header is not provided. JENKINS-8660: loading the build history cause an NPE on the History Widget
-
由 Kohsuke Kawaguchi 提交于
-
由 Kohsuke Kawaguchi 提交于
Yes, this is HUDSON-8656 and not JENKINS-8656.
-
-
由 Kohsuke Kawaguchi 提交于
-
由 Kohsuke Kawaguchi 提交于
* commit 'c628bdd3': First pass at a fix for JENKINS-8592.
-
由 Kohsuke Kawaguchi 提交于
(recording the previous commit 9d7d0d75 by Richie Vos)
-
由 Brian Atkinson 提交于
The problem is that the sending side has no way of knowing when the receiving side has hung up. So when the receiving side hangs up we should be able to read till the stream runs out, then close. Not the optimal solution, but one that should work for now. http://issues.jenkins-ci.org/browse/JENKINS-8592
-
由 Brian Atkinson 提交于
-
由 Brian Atkinson 提交于
HUDSON-8401. This grouping of tests targets all Sunday to *another day of week* cron tabs. There are likely other pairs that could be tested, but this seemed to work out most of the bugs.
-
由 Richie Vos 提交于
-
由 Olivier Lamy 提交于
-
-
由 Jerome Lacoste 提交于
After thinking about it, I don't want to deal with hudsonslave here. jenkinsslave should be found anyway, so that code path should not have been triggered. And cleaning up residual services isn't jenkins job. Otherwise both can't coexist.
-
由 Jerome Lacoste 提交于
After thinking about it, I don't want to deal with hudsonslave here. jenkinsslave should be found anyway, so that code path should not have been triggered. And cleaning up residual services isn't jenkins job. Otherwise both can't coexist.
-
由 Jerome Lacoste 提交于
-
由 Jerome Lacoste 提交于
JENKINS-8698 HudsonTestCase sometimes fails with NPE in tearDown() while trying to free htmlunit resources Not really sure what is happening, but I don't think the build should fail here. So let's try to be more resiliant (try twice loading the page) and don't fail if the exception occurs again.
-
由 Nathan Parry 提交于
Persist a user-requested offline status for a slave across restarts. Previously slaves would come back online if the server was restarted while they were marked 'temporarily offline'. I believe this also addresses JENKINS-7934 and JENKINS-7805 which look like duplicates.
-
-