In IoT applications, many data items are often collected for intelligent control, business analysis, device monitoring, etc. Due to the version upgrade of the application logic, or the hardware adjustment of the device itself, the data collection items may change more frequently. To facilitate the data logging work in such cases, TDengine starting from version 2.2.0.0, it provides a series of interfaces to the schemaless writing method, which eliminates the need to create super tables/sub tables in advance and automatically creates the storage structure corresponding to the data as the data is written to the interface. And when necessary, Schemaless writing will automatically add the required columns to ensure that the data written by the user is stored correctly.
D
dingbo 已提交
7

8
The schemaless writing method creates super tables and their corresponding sub-tables completely indistinguishable from the super tables and sub-tables created directly via SQL. You can write data directly to them via SQL statements. Note that the names of tables created by schemaless writing are based on fixed mapping rules for tag values, so they are not explicitly ideographic and lack readability.
D
dingbo 已提交
9

10
## Schemaless Writing Line Protocol
D
dingbo 已提交
11

12
TDengine's schemaless writing line protocol supports to be compatible with InfluxDB's Line Protocol, OpenTSDB's telnet line protocol, and OpenTSDB's JSON format protocol. However, when using these three protocols, you need to specify in the API the standard of the parsing protocol to be used for the input content.
D
dingbo 已提交
13

14
For the standard writing protocols of InfluxDB and OpenTSDB, please refer to the documentation of each protocol. The following is a description of TDengine's extended protocol, based on InfluxDB's line protocol first. They allow users to control the (super table) schema more granularly.
D
dingbo 已提交
15

16
With the following formatting conventions, Schemaless writing uses a single string to express a data row (multiple rows can be passed into the writing API at once to enable bulk writing).
D
dingbo 已提交
17 18 19 20 21

```json
measurement,tag_set field_set timestamp
```

22
where :
D
dingbo 已提交
23

24
- measurement will be used as the data table name. It will be separated from tag_set by a comma.
25 26 27
- tag_set will be used as tag data in the format `<tag_key>=<tag_value>,<tag_key>=<tag_value>`, i.e. multiple tags' data can be separated by a comma. It is separated from field_set by space.
- field_set will be used as normal column data in the format of `<field_key>=<field_value>,<field_key>=<field_value>`, again using a comma to separate multiple normal columns of data. It is separated from the timestamp by space.
- The timestamp is the primary key corresponding to the data in this row.
D
dingbo 已提交
28

29
All data in tag_set is automatically converted to the NCHAR data type and does not require double quotes (").
D
dingbo 已提交
30

31
In the schemaless writing data line protocol, each data item in the field_set needs to be described with its data type. Let's explain in detail:
D
dingbo 已提交
32

33
- If there are English double quotes on both sides, it indicates the BINARY(32) type. For example, `"abc"`.
34 35
- If there are double quotes on both sides and an L prefix, it means NCHAR(32) type. For example, `L"error message"`.
- Spaces, equal signs (=), commas (,), and double quotes (") need to be escaped with a backslash (\) in front. (All refer to the ASCII character)
36
- Numeric types will be distinguished from data types by the suffix.
D
dingbo 已提交
37

38
| **Serial number** | **Postfix** | **Mapping type** | **Size (bytes)** |
D
dingbo 已提交
39
| -------- | -------- | ------------ | -------------- |
40 41 42 43 44 45
| 1 | none or f64 | double | 8 |
| 2 | f32 | float | 4 |
| 3 | i8 | TinyInt | 1 |
| 4 | i16 | SmallInt | 2 |
| 5 | i32 | Int | 4 |
| 6 | i64 or i | Bigint | 8 |
D
dingbo 已提交
46

47
- `t`, `T`, `true`, `True`, `TRUE`, `f`, `F`, `false`, and `False` will be handled directly as BOOL types.
D
dingbo 已提交
48

49
For example, the following data rows indicate that the t1 label is "3" (NCHAR), the t2 label is "4" (NCHAR), and the t3 label is "t3" to the super table named `st` labeled "t3" (NCHAR), write c1 column as 3 (BIGINT), c2 column as false (BOOL), c3 column is "passit" (BINARY), c4 column is 4 (DOUBLE), and the primary key timestamp is 1626006833639000000 in one row.
D
dingbo 已提交
50 51 52 53 54

```json
st,t1=3,t2=4,t3=t3 c1=3i64,c3="passit",c2=false,c4=4f64 1626006833639000000
```

55
Note that if the wrong case is used when describing the data type suffix, or if the wrong data type is specified for the data, it may cause an error message and cause the data to fail to be written.
D
dingbo 已提交
56

57
## Main processing logic for schemaless writing
D
dingbo 已提交
58

59
Schemaless writes process row data according to the following principles.
D
dingbo 已提交
60

61
1. You can use the following rules to generate the sub-table names: first, combine the measurement name and the key and value of the label  into the next string:
D
dingbo 已提交
62 63 64 65 66

```json
"measurement,tag_key1=tag_value1,tag_key2=tag_value2"
```

67 68
Note that tag_key1, tag_key2 are not the original order of the tags entered by the user but the result of using the tag names in ascending order of the strings. Therefore, tag_key1 is not the first tag entered in the line protocol.
The string's MD5 hash value "md5_val" is calculated after the ranking is completed. The calculation result is then combined with the string to generate the table name: "t_md5_val". "t*" is a fixed prefix that every table generated by this mapping relationship has. 2.
D
dingbo 已提交
69

70 71
2. If the super table obtained by parsing the line protocol does not exist, this super table is created.
If the sub-table obtained by the parse line protocol does not exist, Schemaless creates the sub-table according to the sub-table name determined in steps 1 or 2. 4.
72 73 74 75 76
4. If the specified tag or regular column in the data row does not exist, the corresponding tag or regular column is added to the super table (only incremental).
5. If there are some tag columns or regular columns in the super table that are not specified to take values in a data row, then the values of these columns are set to NULL.
6. For BINARY or NCHAR columns, if the length of the value provided in a data row exceeds the column type limit, the maximum length of characters allowed to be stored in the column is automatically increased (only incremented and not decremented) to ensure complete preservation of the data.
7. If the specified data sub-table already exists, and the specified tag column takes a value different from the saved value this time, the value in the latest data row overwrites the old tag column take value.
8. Errors encountered throughout the processing will interrupt the writing process and return an error code.
D
dingbo 已提交
77 78

:::tip
79
All processing logic of schemaless will still follow TDengine's underlying restrictions on data structures, such as the total length of each row of data cannot exceed
80
16k bytes. See [TAOS SQL Boundary Limits](/taos-sql/limit) for specific constraints in this area.
D
dingbo 已提交
81 82
:::

83
## Time resolution recognition
D
dingbo 已提交
84

85
Three specified modes are supported in the schemaless writing process, as follows:
D
dingbo 已提交
86

87
| **Serial** | **Value** | **Description** |
D
dingbo 已提交
88
| -------- | ------------------- | ------------------------------- |
89 90 91
| 1 | SML_LINE_PROTOCOL | InfluxDB Line Protocol |
| 2 | SML_TELNET_PROTOCOL | OpenTSDB Text Line Protocol | | 2 | SML_TELNET_PROTOCOL | OpenTSDB Text Line Protocol
| 3 | SML_JSON_PROTOCOL | JSON protocol format |
D
dingbo 已提交
92

93
In the SML_LINE_PROTOCOL parsing mode, the user is required to specify the time resolution of the input timestamp. The available time resolutions are shown in the following table.
D
dingbo 已提交
94

95
| **Serial Number** | **Time Resolution Definition** | **Meaning** |
D
dingbo 已提交
96
| -------- | --------------------------------- | -------------- |
97 98 99 100 101 102 103
| 1 | TSDB_SML_TIMESTAMP_NOT_CONFIGURED | Not defined (invalid) |
| 2 | TSDB_SML_TIMESTAMP_HOURS | hour |
| 3 | TSDB_SML_TIMESTAMP_MINUTES | MINUTES
| 4 | TSDB_SML_TIMESTAMP_SECONDS | SECONDS
| 5 | TSDB_SML_TIMESTAMP_MILLI_SECONDS | milliseconds
| 6 | TSDB_SML_TIMESTAMP_MICRO_SECONDS | microseconds
| 7 | TSDB_SML_TIMESTAMP_NANO_SECONDS | nanoseconds |
D
dingbo 已提交
104

105
In SML_TELNET_PROTOCOL and SML_JSON_PROTOCOL modes, the time precision is determined based on the length of the timestamp (in the same way as the OpenTSDB standard operation), and the user-specified time resolution is ignored at this point.
D
dingbo 已提交
106

107
## Data schema mapping rules
D
dingbo 已提交
108

109
This section describes how data for line protocols are mapped to data with a schema. The data measurement in each line protocol is mapped to
110
The tag name in tag_set is the name of the tag in the data schema, and the name in field_set is the column's name. The following data is used as an example to illustrate the mapping rules.
D
dingbo 已提交
111 112 113 114 115

```json
st,t1=3,t2=4,t3=t3 c1=3i64,c3="passit",c2=false,c4=4f64 1626006833639000000
```

116
The row data mapping generates a super table: `st`, which contains three labels of type NCHAR: t1, t2, t3. Five data columns are ts (timestamp), c1 (bigint), c3 (binary), c2 (bool), c4 (bigint). The mapping becomes the following SQL statement.
D
dingbo 已提交
117 118 119 120 121

```json
create stable st (_ts timestamp, c1 bigint, c2 bool, c3 binary(6), c4 bigint) tags(t1 nchar(1), t2 nchar(1), t3 nchar(2))
```

122
## Data schema change handling
D
dingbo 已提交
123

124
This section describes the impact on the data schema for different line protocol data writing cases.
D
dingbo 已提交
125

126
When writing to an explicitly identified field type using the line protocol, subsequent changes to the field's type definition will result in an explicit data schema error, i.e., will trigger a write API report error. As shown below, the
D
dingbo 已提交
127 128

```json
129 130
st,t1=3,t2=4,t3=t3 c1=3i64,c3="passit",c2=false,c4=4 1626006833639000000
st,t1=3,t2=4,t3=t3 c1=3i64,c3="passit",c2=false,c4=4i 1626006833640000000
D
dingbo 已提交
131 132
```

133
The data type mapping in the first row defines column c4 as DOUBLE, but the data in the second row is declared as BIGINT by the numeric suffix, which triggers a parsing error with schemaless writing.
D
dingbo 已提交
134

135
If the line protocol before the column declares the data column as BINARY, the subsequent one requires a longer binary length, which triggers a super table schema change.
D
dingbo 已提交
136 137

```json
138 139
st,t1=3,t2=4,t3=t3 c1=3i64,c5="pass" 1626006833639000000
st,t1=3,t2=4,t3=t3 c1=3i64,c5="passit" 1626006833640000000
D
dingbo 已提交
140 141
```

142
The first line of the line protocol parsing will declare column c5 is a BINARY(4) field, the second line data write will extract column c5 is still a BINARY column. Still, its width is 6, then you need to increase the width of the BINARY field to be able to accommodate the new string.
D
dingbo 已提交
143 144

```json
145 146
st,t1=3,t2=4,t3=t3 c1=3i64 1626006833639000000
st,t1=3,t2=4,t3=t3 c1=3i64,c6="passit" 1626006833640000000
D
dingbo 已提交
147 148
```

149
The second line of data has an additional column c6 of type BINARY(6) compared to the first row. Then a column c6 of type BINARY(6) is automatically added at this point.
D
dingbo 已提交
150

151
## Write integrity
D
dingbo 已提交
152

153
TDengine provides idempotency guarantees for data writing, i.e., you can repeatedly call the API to write data with errors. However, it does not give atomicity guarantees for writing multiple rows of data. During the process of writing numerous rows of data in one batch, some data will be written successfully, and some data will fail.
D
dingbo 已提交
154

155
## Error code
D
dingbo 已提交
156

157
If it is an error in the data itself during the schemaless writing process, the application will get `TSDB_CODE_TSC_LINE_SYNTAX_ERROR` error message, which indicates that the error occurred in writing. The other error codes are consistent with the TDengine and can be obtained via the `taos_errstr()` to get the specific cause of the error.