提交 9b302c1a 编写于 作者: G Geert Uytterhoeven 提交者: Simon Horman

drivers: sh: Disable legacy default PM Domain on emev2

EMMA Mobile EV2 doesn't have MSTP clocks. All its device drivers manage
clocks explicitly, without relying on Runtime PM, so it doesn't need the
legacy default PM Domain.
Signed-off-by: NGeert Uytterhoeven <geert+renesas@glider.be>
Reviewed-by: NUlf Hansson <ulf.hansson@linaro.org>
Signed-off-by: NSimon Horman <horms+renesas@verge.net.au>
上级 6ff33f39
......@@ -35,8 +35,7 @@ static struct pm_clk_notifier_block platform_bus_notifier = {
static int __init sh_pm_runtime_init(void)
{
if (IS_ENABLED(CONFIG_ARCH_SHMOBILE_MULTI)) {
if (!of_machine_is_compatible("renesas,emev2") &&
!of_machine_is_compatible("renesas,r7s72100") &&
if (!of_machine_is_compatible("renesas,r7s72100") &&
#ifndef CONFIG_PM_GENERIC_DOMAINS_OF
!of_machine_is_compatible("renesas,r8a73a4") &&
!of_machine_is_compatible("renesas,r8a7740") &&
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册