diff --git a/en/application-dev/reference/apis/js-apis-thermal.md b/en/application-dev/reference/apis/js-apis-thermal.md index 5d6648171ee97febc156025f1501c8500a0cb011..f1b246f11ff17c4b2b31a1ca16210d5ce11c48bc 100644 --- a/en/application-dev/reference/apis/js-apis-thermal.md +++ b/en/application-dev/reference/apis/js-apis-thermal.md @@ -3,7 +3,7 @@ > ![icon-note.gif](public_sys-resources/icon-note.gif) **NOTE** > The initial APIs of this module are supported since API version 8. Newly added APIs will be marked with a superscript to indicate their earliest API version. -The Thermal Manager module provides APIs for listening to the device thermal status. +This module provides thermal level-related callback and query APIs to obtain the information required for thermal control. ## Modules to Import @@ -17,15 +17,17 @@ import thermal from '@ohos.thermal'; Represents the thermal level. +**System capability:** SystemCapability.PowerManager.ThermalManager + | Name | Default Value | Description | | ---------- | ---- | ---------------------------------------- | -| COOL | 0 | The device is cool, and services are not restricted.
**System capability:** SystemCapability.PowerManager.ThermalManager| -| NORMAL | 1 | The device is operational but is not cool. You need to pay attention to its heating.
**System capability:** SystemCapability.PowerManager.ThermalManager| -| WARM | 2 | The device is warm. You need to stop or delay some imperceptible services.
**System capability:** SystemCapability.PowerManager.ThermalManager| -| HOT | 3 | The device is heating up. You need to stop all imperceptible services and downgrade or reduce the load of other services.
**System capability:** SystemCapability.PowerManager.ThermalManager| -| OVERHEATED | 4 | The device is overheated. You need to stop all imperceptible services and downgrade or reduce the load of major services.
**System capability:** SystemCapability.PowerManager.ThermalManager| -| WARNING | 5 | The device is overheated and is about to enter the emergency state. You need to stop all imperceptible services and downgrade major services to the maximum extent.
**System capability:** SystemCapability.PowerManager.ThermalManager| -| EMERGENCY | 6 | The device has entered the emergency state. You need to stop all services except those for the emergency help purposes.
**System capability:** SystemCapability.PowerManager.ThermalManager| +| COOL | 0 | The device is cool, and services are not restricted.| +| NORMAL | 1 | The device is operational but is not cool. You need to pay attention to its heating.| +| WARM | 2 | The device is warm. You need to stop or delay some imperceptible services.| +| HOT | 3 | The device is heating up. You need to stop all imperceptible services and downgrade or reduce the load of other services.| +| OVERHEATED | 4 | The device is overheated. You need to stop all imperceptible services and downgrade or reduce the load of major services.| +| WARNING | 5 | The device is overheated and is about to enter the emergency state. You need to stop all imperceptible services and downgrade major services to the maximum extent.| +| EMERGENCY | 6 | The device has entered the emergency state. You need to stop all services except those for the emergency help purposes.| ## thermal.subscribeThermalLevel