diff --git a/drivers/gpu/drm/panel/panel-simple.c b/drivers/gpu/drm/panel/panel-simple.c index a1cd431e17a6791247d4f49b1e8f0562e8796451..39e9dffe07d970ccda219d8e15b520676b0862ea 100644 --- a/drivers/gpu/drm/panel/panel-simple.c +++ b/drivers/gpu/drm/panel/panel-simple.c @@ -713,7 +713,12 @@ static const struct display_timing hannstar_hsd070pww1_timing = { .hactive = { 1280, 1280, 1280 }, .hfront_porch = { 1, 1, 10 }, .hback_porch = { 1, 1, 10 }, - .hsync_len = { 52, 158, 661 }, + /* + * According to the data sheet, the minimum horizontal blanking interval + * is 54 clocks (1 + 52 + 1), but tests with a Nitrogen6X have shown the + * minimum working horizontal blanking interval to be 60 clocks. + */ + .hsync_len = { 58, 158, 661 }, .vactive = { 800, 800, 800 }, .vfront_porch = { 1, 1, 10 }, .vback_porch = { 1, 1, 10 },