提交 3c209620 编写于 作者: Y Yossi Etigin 提交者: Roland Dreier

IPoIB: Do not print error messages for multicast join retries

When IPoIB tries to join a multicast group, and the SA module's SM
address handle is NULL (because of an SM change, etc), the join
returns with -EAGAIN status.  In that case, don't print an error
message unless multicast debugging is enabled.
Signed-off-by: NYossi Etigin <yosefe@voltaire.com>
Signed-off-by: NRoland Dreier <rolandd@cisco.com>
上级 cbbe1efa
...@@ -409,7 +409,7 @@ static int ipoib_mcast_join_complete(int status, ...@@ -409,7 +409,7 @@ static int ipoib_mcast_join_complete(int status,
} }
if (mcast->logcount++ < 20) { if (mcast->logcount++ < 20) {
if (status == -ETIMEDOUT) { if (status == -ETIMEDOUT || status == -EAGAIN) {
ipoib_dbg_mcast(priv, "multicast join failed for %pI6, status %d\n", ipoib_dbg_mcast(priv, "multicast join failed for %pI6, status %d\n",
mcast->mcmember.mgid.raw, status); mcast->mcmember.mgid.raw, status);
} else { } else {
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!