提交 1c51089f 编写于 作者: M Mahesh Salgaonkar 提交者: Benjamin Herrenschmidt

powerpc/book3s: Return from interrupt if coming from evil context.

We can get machine checks from any context. We need to make sure that
we handle all of them correctly. If we are coming from hypervisor user-space,
we can continue in host kernel in virtual mode to deliver the MC event.
If we got woken up from power-saving mode then we may come in with one of
the following state:
 a. No state loss
 b. Supervisor state loss
 c. Hypervisor state loss
For (a) and (b), we go back to nap again. State (c) is fatal, keep spinning.

For all other context which we not sure of queue up the MCE event and return
from the interrupt.
Signed-off-by: NMahesh Salgaonkar <mahesh@linux.vnet.ibm.com>
Signed-off-by: NBenjamin Herrenschmidt <benh@kernel.crashing.org>
上级 1e9b4507
......@@ -155,6 +155,24 @@ machine_check_pSeries_1:
*/
HMT_MEDIUM_PPR_DISCARD
SET_SCRATCH0(r13) /* save r13 */
#ifdef CONFIG_PPC_P7_NAP
BEGIN_FTR_SECTION
/* Running native on arch 2.06 or later, check if we are
* waking up from nap. We only handle no state loss and
* supervisor state loss. We do -not- handle hypervisor
* state loss at this time.
*/
mfspr r13,SPRN_SRR1
rlwinm. r13,r13,47-31,30,31
beq 9f
/* waking up from powersave (nap) state */
cmpwi cr1,r13,2
/* Total loss of HV state is fatal. let's just stay stuck here */
bgt cr1,.
9:
END_FTR_SECTION_IFSET(CPU_FTR_HVMODE | CPU_FTR_ARCH_206)
#endif /* CONFIG_PPC_P7_NAP */
EXCEPTION_PROLOG_0(PACA_EXMC)
BEGIN_FTR_SECTION
b machine_check_pSeries_early
......@@ -818,6 +836,70 @@ BEGIN_FTR_SECTION
bl .save_nvgprs
addi r3,r1,STACK_FRAME_OVERHEAD
bl .machine_check_early
ld r12,_MSR(r1)
#ifdef CONFIG_PPC_P7_NAP
/*
* Check if thread was in power saving mode. We come here when any
* of the following is true:
* a. thread wasn't in power saving mode
* b. thread was in power saving mode with no state loss or
* supervisor state loss
*
* Go back to nap again if (b) is true.
*/
rlwinm. r11,r12,47-31,30,31 /* Was it in power saving mode? */
beq 4f /* No, it wasn;t */
/* Thread was in power saving mode. Go back to nap again. */
cmpwi r11,2
bne 3f
/* Supervisor state loss */
li r0,1
stb r0,PACA_NAPSTATELOST(r13)
3: MACHINE_CHECK_HANDLER_WINDUP
GET_PACA(r13)
ld r1,PACAR1(r13)
b .power7_enter_nap_mode
4:
#endif
/*
* Check if we are coming from hypervisor userspace. If yes then we
* continue in host kernel in V mode to deliver the MC event.
*/
rldicl. r11,r12,4,63 /* See if MC hit while in HV mode. */
beq 5f
andi. r11,r12,MSR_PR /* See if coming from user. */
bne 9f /* continue in V mode if we are. */
5:
#ifdef CONFIG_KVM_BOOK3S_64_HV
/*
* We are coming from kernel context. Check if we are coming from
* guest. if yes, then we can continue. We will fall through
* do_kvm_200->kvmppc_interrupt to deliver the MC event to guest.
*/
lbz r11,HSTATE_IN_GUEST(r13)
cmpwi r11,0 /* Check if coming from guest */
bne 9f /* continue if we are. */
#endif
/*
* At this point we are not sure about what context we come from.
* Queue up the MCE event and return from the interrupt.
* But before that, check if this is an un-recoverable exception.
* If yes, then stay on emergency stack and panic.
*/
andi. r11,r12,MSR_RI
bne 2f
1: addi r3,r1,STACK_FRAME_OVERHEAD
bl .unrecoverable_exception
b 1b
2:
/*
* Return from MC interrupt.
* TODO: Queue up the MCE event so that we can log it later.
*/
MACHINE_CHECK_HANDLER_WINDUP
rfid
9:
/* Deliver the machine check to host kernel in V mode. */
MACHINE_CHECK_HANDLER_WINDUP
b machine_check_pSeries
......
......@@ -84,6 +84,7 @@ _GLOBAL(power7_nap)
std r9,_MSR(r1)
std r1,PACAR1(r13)
_GLOBAL(power7_enter_nap_mode)
#ifdef CONFIG_KVM_BOOK3S_HV_POSSIBLE
/* Tell KVM we're napping */
li r4,KVM_HWTHREAD_IN_NAP
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册