提交 3830c7a4 编写于 作者: M Marcin Krzeminski 提交者: Peter Maydell

m25p80: Fix WINBOND fast read command handling

This commit fix obvious bug in WINBOND command handling.
Datasheet states that default dummy cycles is 8 so fix it.
Signed-off-by: NMarcin Krzeminski <marcin.krzeminski@nokia.com>
Message-id: 1466755631-25201-11-git-send-email-marcin.krzeminski@nokia.com
Signed-off-by: NPeter Maydell <peter.maydell@linaro.org>
上级 dadb2f90
......@@ -738,6 +738,9 @@ static void decode_fast_read_cmd(Flash *s)
s->needed_bytes = get_addr_length(s);
switch (get_man(s)) {
/* Dummy cycles - modeled with bytes writes instead of bits */
case MAN_WINBOND:
s->needed_bytes += 8;
break;
case MAN_NUMONYX:
s->needed_bytes += extract32(s->volatile_cfg, 4, 4);
break;
......@@ -768,7 +771,7 @@ static void decode_dio_read_cmd(Flash *s)
/* Dummy cycles modeled with bytes writes instead of bits */
switch (get_man(s)) {
case MAN_WINBOND:
s->needed_bytes = 4;
s->needed_bytes += 8;
break;
case MAN_SPANSION:
s->needed_bytes += SPANSION_CONTINUOUS_READ_MODE_CMD_LEN;
......@@ -807,7 +810,7 @@ static void decode_qio_read_cmd(Flash *s)
/* Dummy cycles modeled with bytes writes instead of bits */
switch (get_man(s)) {
case MAN_WINBOND:
s->needed_bytes = 6;
s->needed_bytes += 8;
break;
case MAN_SPANSION:
s->needed_bytes += SPANSION_CONTINUOUS_READ_MODE_CMD_LEN;
......