From bf2788218ad29719467260aa4ecad6dc31c97046 Mon Sep 17 00:00:00 2001 From: Luyao Huang Date: Wed, 19 Aug 2015 11:56:33 +0800 Subject: [PATCH] qemu: Update blkio.weight value after successful set https://bugzilla.redhat.com/show_bug.cgi?id=1253107 Make a call virCgroupGetBlkioWeight to re-read blkio.weight right after it is set in order to keep internal data up-to-date. Signed-off-by: Luyao Huang --- src/qemu/qemu_driver.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/src/qemu/qemu_driver.c b/src/qemu/qemu_driver.c index 57098ee5a5..b263ce0c38 100644 --- a/src/qemu/qemu_driver.c +++ b/src/qemu/qemu_driver.c @@ -9183,7 +9183,8 @@ qemuDomainSetBlkioParameters(virDomainPtr dom, virTypedParameterPtr param = ¶ms[i]; if (STREQ(param->field, VIR_DOMAIN_BLKIO_WEIGHT)) { - if (virCgroupSetBlkioWeight(priv->cgroup, param->value.ui) < 0) + if (virCgroupSetBlkioWeight(priv->cgroup, param->value.ui) < 0 || + virCgroupGetBlkioWeight(priv->cgroup, &def->blkio.weight) < 0) ret = -1; } else if (STREQ(param->field, VIR_DOMAIN_BLKIO_DEVICE_WEIGHT) || STREQ(param->field, VIR_DOMAIN_BLKIO_DEVICE_READ_IOPS) || -- GitLab