提交 d66c2950 编写于 作者: M Marcel Holtmann 提交者: Johan Hedberg

Bluetooth: Use same LE min/max connection event length during update

During LE connection establishment the value 0x0000 is used for min/max
connection event length. So use the same value when the peripheral is
requesting an update of the the connection paramters.

For some reason the value 0x0001 got used in the connection update and
0x0000 in the connection creation. Using the same value for both just
makes sense.
Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
上级 3698d704
......@@ -225,8 +225,8 @@ void hci_le_conn_update(struct hci_conn *conn, u16 min, u16 max,
cp.conn_interval_max = cpu_to_le16(max);
cp.conn_latency = cpu_to_le16(latency);
cp.supervision_timeout = cpu_to_le16(to_multiplier);
cp.min_ce_len = __constant_cpu_to_le16(0x0001);
cp.max_ce_len = __constant_cpu_to_le16(0x0001);
cp.min_ce_len = __constant_cpu_to_le16(0x0000);
cp.max_ce_len = __constant_cpu_to_le16(0x0000);
hci_send_cmd(hdev, HCI_OP_LE_CONN_UPDATE, sizeof(cp), &cp);
}
......
Markdown is supported
0% .