[S390] zcrypt: Do not remove coprocessor for error 8/72

In a case where the number of the input data is bigger than the
modulus of the key, the coprocessor adapters will report an 8/72
error. This case is not caught yet, thus the adapter will be taken
offline. To prevent this, we return an -EINVAL instead.
Signed-off-by: NFelix Beck <felix.beck@de.ibm.com>
Signed-off-by: NMartin Schwidefsky <schwidefsky@de.ibm.com>
上级 0b665d77
......@@ -373,6 +373,8 @@ static int convert_type86(struct zcrypt_device *zdev,
zdev->max_mod_size = PCICC_MAX_MOD_SIZE_OLD;
return -EAGAIN;
}
if (service_rc == 8 && service_rs == 72)
return -EINVAL;
zdev->online = 0;
return -EAGAIN; /* repeat the request on a different device. */
}
......
......@@ -470,6 +470,8 @@ static int convert_type86_ica(struct zcrypt_device *zdev,
}
if (service_rc == 12 && service_rs == 769)
return -EINVAL;
if (service_rc == 8 && service_rs == 72)
return -EINVAL;
zdev->online = 0;
return -EAGAIN; /* repeat the request on a different device. */
}
......