提交 e60ee41a 编写于 作者: S Siva Reddy Kallam 提交者: David S. Miller

tg3: Enable PHY reset in MTU change path for 5720

A customer noticed RX path hang when MTU is changed on the fly while
running heavy traffic with NCSI enabled for 5717 and 5719. Since 5720
belongs to same ASIC family, we observed same issue and same fix
could solve this problem for 5720.
Signed-off-by: NSiva Reddy Kallam <siva.kallam@broadcom.com>
Signed-off-by: NMichael Chan <michael.chan@broadcom.com>
Signed-off-by: NDavid S. Miller <davem@davemloft.net>
上级 4419bb1c
......@@ -14239,7 +14239,8 @@ static int tg3_change_mtu(struct net_device *dev, int new_mtu)
*/
if (tg3_asic_rev(tp) == ASIC_REV_57766 ||
tg3_asic_rev(tp) == ASIC_REV_5717 ||
tg3_asic_rev(tp) == ASIC_REV_5719)
tg3_asic_rev(tp) == ASIC_REV_5719 ||
tg3_asic_rev(tp) == ASIC_REV_5720)
reset_phy = true;
err = tg3_restart_hw(tp, reset_phy);
......