diff --git a/arch/powerpc/platforms/pseries/eeh_pseries.c b/arch/powerpc/platforms/pseries/eeh_pseries.c index 19506f935737d2ee7c27a16d1ecc909cc4b6c518..b456b157d33d107842a42d3b0c3d0da36e9ea121 100644 --- a/arch/powerpc/platforms/pseries/eeh_pseries.c +++ b/arch/powerpc/platforms/pseries/eeh_pseries.c @@ -83,7 +83,11 @@ static int pseries_eeh_init(void) ibm_configure_pe = rtas_token("ibm,configure-pe"); ibm_configure_bridge = rtas_token("ibm,configure-bridge"); - /* necessary sanity check */ + /* + * Necessary sanity check. We needn't check "get-config-addr-info" + * and its variant since the old firmware probably support address + * of domain/bus/slot/function for EEH RTAS operations. + */ if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE) { pr_warning("%s: RTAS service invalid\n", __func__); @@ -102,12 +106,6 @@ static int pseries_eeh_init(void) pr_warning("%s: RTAS service invalid\n", __func__); return -EINVAL; - } else if (ibm_get_config_addr_info2 == RTAS_UNKNOWN_SERVICE && - ibm_get_config_addr_info == RTAS_UNKNOWN_SERVICE) { - pr_warning("%s: RTAS service and " - " invalid\n", - __func__); - return -EINVAL; } else if (ibm_configure_pe == RTAS_UNKNOWN_SERVICE && ibm_configure_bridge == RTAS_UNKNOWN_SERVICE) { pr_warning("%s: RTAS service and "