mmc: sunxi: Always set signal delay to 0 for A64
Experience have shown that the using the autocalibration could severely degrade the performances of the MMC bus. Allwinner is using in its BSP a delay set to 0 for all the modes but HS400. Remove the calibration code for now, and add comments to document our findings. Reviewed-by: NAndre Przywara <andre.przywara@arm.com> Signed-off-by: NMaxime Ripard <maxime.ripard@free-electrons.com> Tested-by: NFlorian Vaussard <florian.vaussard@heig-vd.ch> Acked-by: NChen-Yu Tsai <wens@csie.org> Signed-off-by: NUlf Hansson <ulf.hansson@linaro.org>