提交 4d6f7201 编写于 作者: S Sujith Manoharan 提交者: John W. Linville

ath9k: Fix regulatory compliance

The maximum permissible values for noise floor in ETSI
and Japan domains have been updated with new EU
regulations for CCA detection. Adjust the values in the
driver accordingly.
Signed-off-by: NSujith Manoharan <c_manoha@qca.qualcomm.com>
Signed-off-by: NJohn W. Linville <linville@tuxdriver.com>
上级 42dd98b0
......@@ -338,9 +338,8 @@
#define AR_PHY_CCA_NOM_VAL_9300_5GHZ -115
#define AR_PHY_CCA_MIN_GOOD_VAL_9300_2GHZ -125
#define AR_PHY_CCA_MIN_GOOD_VAL_9300_5GHZ -125
#define AR_PHY_CCA_MAX_GOOD_VAL_9300_2GHZ -95
#define AR_PHY_CCA_MAX_GOOD_VAL_9300_5GHZ -100
#define AR_PHY_CCA_MAX_GOOD_VAL_9300_2GHZ -60
#define AR_PHY_CCA_MAX_GOOD_VAL_9300_5GHZ -60
#define AR_PHY_CCA_MAX_GOOD_VAL_9300_FCC_2GHZ -95
#define AR_PHY_CCA_MAX_GOOD_VAL_9300_FCC_5GHZ -100
......