iio: adc: max9611: Fix temperature reading in probe
commit b9ddd5091160793ee9fac10da765cf3f53d2aaf0 upstream. The max9611 driver reads the die temperature at probe time to validate the communication channel. Use the actual read value to perform the test instead of the read function return value, which was mistakenly used so far. The temperature reading test was only successful because the 0 return value is in the range of supported temperatures. Fixes: 69780a3b ("iio: adc: Add Maxim max9611 ADC driver") Signed-off-by: NJacopo Mondi <jacopo+renesas@jmondi.org> Cc: <Stable@vger.kernel.org> Signed-off-by: NJonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: NGreg Kroah-Hartman <gregkh@linuxfoundation.org>