hwmon: (lm90) Define status bits
Add bit defines for the status register. And add a function lm90_is_tripped() which will read status register and return tripped or not, then lm90_alert can call it directly, and in the future the IRQ thread also can use it. [JD: Adjusted to include all the new MAX6696 status flags.] Signed-off-by: NWei Ni <wni@nvidia.com> Signed-off-by: NJean Delvare <khali@linux-fr.org>