# Generic thermal sysfs drivers configuration
#

menuconfig THERMAL
6
	tristate "Generic Thermal sysfs driver"
Z
Zhang Rui 已提交
7 8 9 10
	help
	  Generic Thermal Sysfs driver offers a generic mechanism for
	  thermal management. Usually it's made up of one or more thermal
	  zone and cooling device.
11
	  Each thermal zone contains its own temperature, trip points,
Z
Zhang Rui 已提交
12 13
	  cooling devices.
	  All platforms with ACPI thermal support can use this driver.
14
	  If you want this support, you should say Y or M here.
15

Z
Zhang Rui 已提交
16 17
if THERMAL

18
config THERMAL_HWMON
19
	bool
20
	depends on HWMON=y || HWMON=THERMAL
21
	default y
22

Z
Zhang Rui 已提交
23 24 25 26 27 28 29 30 31
choice
	prompt "Default Thermal governor"
	default THERMAL_DEFAULT_GOV_STEP_WISE
	help
	  This option sets which thermal governor shall be loaded at
	  startup. If in doubt, select 'step_wise'.

config THERMAL_DEFAULT_GOV_STEP_WISE
	bool "step_wise"
32
	select THERMAL_GOV_STEP_WISE
Z
Zhang Rui 已提交
33 34 35 36 37 38
	help
	  Use the step_wise governor as default. This throttles the
	  devices one step at a time.

config THERMAL_DEFAULT_GOV_FAIR_SHARE
	bool "fair_share"
39
	select THERMAL_GOV_FAIR_SHARE
Z
Zhang Rui 已提交
40 41 42 43 44 45 46
	help
	  Use the fair_share governor as default. This throttles the
	  devices based on their 'contribution' to a zone. The
	  contribution should be provided through platform data.

config THERMAL_DEFAULT_GOV_USER_SPACE
	bool "user_space"
47
	select THERMAL_GOV_USER_SPACE
Z
Zhang Rui 已提交
48 49 50 51 52 53
	help
	  Select this if you want to let the user space manage the
	  lpatform thermals.

endchoice

54
config THERMAL_GOV_FAIR_SHARE
Z
Zhang Rui 已提交
55 56 57 58
	bool "Fair-share thermal governor"
	help
	  Enable this to manage platform thermals using fair-share governor.

59
config THERMAL_GOV_STEP_WISE
Z
Zhang Rui 已提交
60 61 62 63
	bool "Step_wise thermal governor"
	help
	  Enable this to manage platform thermals using a simple linear

64
config THERMAL_GOV_USER_SPACE
Z
Zhang Rui 已提交
65 66 67 68
	bool "User_space thermal governor"
	help
	  Enable this to let the user space manage the platform thermals.

69
config CPU_THERMAL
70
	bool "generic cpu cooling support"
Z
Zhang Rui 已提交
71
	depends on CPU_FREQ
72
	select CPU_FREQ_TABLE
73 74
	help
	  This implements the generic cpu cooling mechanism through frequency
75 76
	  reduction. An ACPI version of this already exists
	  (drivers/acpi/processor_thermal.c).
77 78
	  This will be useful for platforms using the generic thermal interface
	  and not the ACPI interface.
79

80 81
	  If you want this support, you should say Y here.

82 83 84 85 86 87 88 89
config THERMAL_EMULATION
	bool "Thermal emulation mode support"
	help
	  Enable this option to make a emul_temp sysfs node in thermal zone
	  directory to support temperature emulation. With emulation sysfs node,
	  user can manually input temperature and test the different trip
	  threshold behaviour for simulation purpose.

90 91 92 93
	  WARNING: Be careful while enabling this option on production systems,
	  because userland can easily disable the thermal policy by simply
	  flooding this sysfs node with low temperature values.

94 95 96 97 98 99 100 101 102 103 104
config IMX_THERMAL
	tristate "Temperature sensor driver for Freescale i.MX SoCs"
	depends on CPU_THERMAL
	depends on MFD_SYSCON
	depends on OF
	help
	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
	  It supports one critical trip point and one passive trip point.  The
	  cpufreq is used as the cooling device to throttle CPUs when the
	  passive trip is crossed.

105 106 107
config SPEAR_THERMAL
	bool "SPEAr thermal sensor driver"
	depends on PLAT_SPEAR
108
	depends on OF
109 110 111
	help
	  Enable this to plug the SPEAr thermal sensor driver into the Linux
	  thermal framework
112 113 114 115 116 117 118

config RCAR_THERMAL
	tristate "Renesas R-Car thermal driver"
	depends on ARCH_SHMOBILE
	help
	  Enable this to plug the R-Car thermal sensor driver into the Linux
	  thermal framework
119

120 121 122 123 124 125 126 127
config KIRKWOOD_THERMAL
	tristate "Temperature sensor on Marvell Kirkwood SoCs"
	depends on ARCH_KIRKWOOD
	depends on OF
	help
	  Support for the Kirkwood thermal sensor driver into the Linux thermal
	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.

128 129
config EXYNOS_THERMAL
	tristate "Temperature sensor on Samsung EXYNOS"
Z
Zhang Rui 已提交
130
	depends on (ARCH_EXYNOS4 || ARCH_EXYNOS5)
Z
Zhang Rui 已提交
131
	depends on CPU_THERMAL
132
	help
133
	  If you say yes here you get support for TMU (Thermal Management
134
	  Unit) on SAMSUNG EXYNOS series of SoC.
135

136 137 138 139 140 141 142 143
config DOVE_THERMAL
	tristate "Temperature sensor on Marvell Dove SoCs"
	depends on ARCH_DOVE
	depends on OF
	help
	  Support for the Dove thermal sensor driver in the Linux thermal
	  framework.

144 145 146 147 148 149 150 151 152 153
config DB8500_THERMAL
	bool "DB8500 thermal management"
	depends on ARCH_U8500
	default y
	help
	  Adds DB8500 thermal management implementation according to the thermal
	  management framework. A thermal zone with several trip points will be
	  created. Cooling devices can be bound to the trip points to cool this
	  thermal zone if trip points reached.

154 155 156 157 158 159 160 161
config ARMADA_THERMAL
	tristate "Armada 370/XP thermal management"
	depends on ARCH_MVEBU
	depends on OF
	help
	  Enable this option if you want to have support for thermal management
	  controller present in Armada 370 and Armada XP SoC.

162 163 164 165 166 167 168 169 170 171
config DB8500_CPUFREQ_COOLING
	tristate "DB8500 cpufreq cooling"
	depends on ARCH_U8500
	depends on CPU_THERMAL
	default y
	help
	  Adds DB8500 cpufreq cooling devices, and these cooling devices can be
	  bound to thermal zone trip points. When a trip point reached, the
	  bound cpufreq cooling device turns active to set CPU frequency low to
	  cool down the CPU.
172

173 174 175 176 177 178 179 180 181 182
config INTEL_POWERCLAMP
	tristate "Intel PowerClamp idle injection driver"
	depends on THERMAL
	depends on X86
	depends on CPU_SUP_INTEL
	help
	  Enable this to enable Intel PowerClamp idle injection driver. This
	  enforce idle time which results in more package C-state residency. The
	  user interface is exposed via generic thermal framework.

183 184
config X86_PKG_TEMP_THERMAL
	tristate "X86 package temperature thermal driver"
185
	depends on X86_THERMAL_VECTOR
186 187 188 189 190 191 192 193
	select THERMAL_GOV_USER_SPACE
	default m
	help
	  Enable this to register CPU digital sensor for package temperature as
	  thermal zone. Each package will have its own thermal zone. There are
	  two trip points which can be set by user to get notifications via thermal
	  notification methods.

194 195 196
menu "Texas Instruments thermal drivers"
source "drivers/thermal/ti-soc-thermal/Kconfig"
endmenu
197

Z
Zhang Rui 已提交
198
endif