提交 d20cc4c1 编写于 作者: V Vladimir Zapolskiy 提交者: Kukjin Kim

ARM: S5PC100: use dma-pl330 device name for clock

This change replaces s3c-pl330.x clock device names with dma-pl330.x,
otherwise there won't be a correspondence between clock device name
and amba device name, thus clocks can't be enabled.

Fixes runtime errors on clk_get() from drivers/dma/pl330.c:
  dma-pl330 dma-pl330.0: Cannot get operation clock.
  dma-pl330: probe of dma-pl330.0 failed with error -22
Signed-off-by: NVladimir Zapolskiy <vz@mleia.com>
Acked-by: NBoojin Kim <boojin.kim@samsung.com>
Signed-off-by: NKukjin Kim <kgene.kim@samsung.com>
上级 2c929420
......@@ -455,13 +455,13 @@ static struct clk init_clocks_off[] = {
.ctrlbit = (1 << 2),
}, {
.name = "pdma",
.devname = "s3c-pl330.1",
.devname = "dma-pl330.1",
.parent = &clk_div_d1_bus.clk,
.enable = s5pc100_d1_0_ctrl,
.ctrlbit = (1 << 1),
}, {
.name = "pdma",
.devname = "s3c-pl330.0",
.devname = "dma-pl330.0",
.parent = &clk_div_d1_bus.clk,
.enable = s5pc100_d1_0_ctrl,
.ctrlbit = (1 << 0),
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册